Credits and licences
CT images and labels
TotalSegmentator CT dataset v3.0.0. Wasserthal J, Breit H-C, Meyer MT, et al. TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images. Radiology: Artificial Intelligence 2023;5(5):e230024, doi:10.1148/ryai.230024. Dataset: doi:10.5281/zenodo.22688904, licensed under CC BY 4.0. Changes: slices and label maps were cut from the CT images and the segmentation masks; the face and the skin of the head were removed from the whole-body case; typical levels and volumes were measured on the masks of 1,119 subjects.
MR images and labels
TotalSegmentator MRI dataset v2.0.0. Akinci D'Antonoli T, Berger LK, Indrakanti AK, et al. TotalSegmentator MRI: Robust Sequence-independent Segmentation of Multiple Anatomic Structures in MRI. Radiology 2025;314(2):e241613, doi:10.1148/radiol.241613. Dataset: doi:10.5281/zenodo.14710732, used with the permission of the authors. Changes: slices and label maps were cut from the MR image and the segmentation masks.
Additional labels
Liver segments, vertebrae on MRI, trunk muscles, lung vessels, intervertebral discs, body cavities and structures of the head and neck were segmented on the images with the TotalSegmentator software (Apache-2.0). Heart chambers, brain tissue and further structures of the head were segmented with the CADS model (Xu M, et al.): CADS-model-open v1.0.0 weights, CC BY-SA 4.0; for structures of the head, CADS-model-research v1.0.0 weights, CC BY-NC-SA 4.0, used in the app with the permission of the authors.
Chest radiographs
NIH Chest X-ray dataset (ChestX-ray14), download site. The NIH Clinical Center is the data provider. Wang X, Peng Y, Lu L, Lu Z, Bagheri M, Summers RM. ChestX-ray8: Hospital-scale Chest X-ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases. IEEE CVPR 2017, doi:10.1109/CVPR.2017.369. Changes: films were cropped, resampled to square pixels and resized.
Outlines of the heart and lungs
CheXmask database v1.0.0. Gaggion N, Mosquera C, Mansilla L, et al. physionet.org/content/chexmask-cxr-segmentation-data/1.0.0, licensed under CC BY 4.0. Changes: masks were converted to outlines, and the heart outline was trimmed to the lung border.
Findings on the films
Boxes of findings come from two sources. NIH BBox_List_2017, drawn by a radiologist: Wang X, Peng Y, Lu L, Lu Z, Bagheri M, Summers RM, IEEE CVPR 2017, doi:10.1109/CVPR.2017.369. RSNA Pneumonia Detection Challenge, films read by at least three radiologists: Shih G, Wu CC, Halabi SS, et al. Radiology: Artificial Intelligence 2019;1(1):e180041, doi:10.1148/ryai.2019180041. RSNA terms: you may access and use these de-identified imaging datasets and annotations for the purposes of academic research and education, and other commercial or non-commercial purposes as long as you agree to abide by the provisions: not to make any attempt to identify or contact any individual(s), and, if you share or re-distribute the data in any form, to meet the attribution requirements. Changes: the boxes of Infiltrate and Pneumonia (NIH) and of Lung Opacity (RSNA) are shown as one finding, “lung opacity”; films were cropped at the border, resampled and resized. RSNA annotations were also used to select films read as normal.
Simulated films
Some chest films are simulated: they are computed from the CT images above.